Page EN-4 Pointek ULS200 – QUICK START MANUAL A5E32268616
mmmmm
English
Electronics/Enclosure
• termination: terminal block, 2.5 mm
2
(14 AWG) solid 1.5 mm
2
(16 AWG)
stranded, maximum
•material: plastic
OR
epoxy coated aluminum with gasket
• ingress protection: Type 6/NEMA 6/IP67
1
• cable inlet: 2 x ½" NPT or 2 x PG 13.5
Transdu cer
• material: ETFE or PVDF copolymer
• mounting: threaded: 2" NPT, 2" BSPT, or 2" G
optional flange adapter, to 3" ASME, DIN 65PN10, and JIS
10K3B
Approvals
See product nameplate.
Plastic enclosure:
•General CSA
US/C
, FM, CE
2
, C-TICK
• Hazardous
Non-incendive (Canada) CSA Class I, II, Div. 2, Gr. A, B, C, D, F, G
Class III
Epoxy coated aluminum enclosure:
•General
CSA
US/C
, FM, CE
2
, C-TICK
• Hazardous
Explosion Proof (Canada) CSA Class I, Div. 1, Gr. A, B, C, D
Class II, Gr. E, F, G
Class III
Explosion Proof (USA) FM Class I, Div. 1, Gr. A, B, C, D T4
Class I, Zone 1, IIC T4
Class II, III, Div. 1, Gr. E, F, G T4
Flame Proof (Europe) ATEX II 2G EEx dmb IIC T5 Gb
Flame Proof (Australia) ANZEx Ex ds IIC T5 IP65/IP67 Class I, Zone 1
DIP A21 T5 IP65/IP67
Flame Proof (Brazil) INMETRO DNV 12.0074 X
Ex d mb IIC T5 Gb
IP65/IP67
-20 ºC
≤ T
a
≤ +60 ºC
DNV #OCP 0017
ABNT NBR IEC 60079-0:2008,
ABNT NBR IEC 60079-1:2009 e
ABNT NBR IEC 60079-18:2010
1.
Use only approved, suitable size hubs for watertight applications.
2.