200 MB. Sub directories on the USB stick will have following structure: ConBox_<BOX ID>/<Cu
rrentTime>Sample:ConBox_J47110815/20180318T191647
JSON Code:
{
"Commands": [
{
"Cmd":"CopyArchivedLogsToUsbStick",
"DeleteAfterCopy":"false"
}
]
}
To store the file locally, disable the log file upload.
Change system time
For the case that the system time should have been changed so that agent runtime is no longer
able to connect to Industrial IoT, you can retrieve the backend time to correct the system time.
The following command provides the possibility to change the system time manually via
ConBox_Commands.json file on the USB stick.
JSON Code:
{
"Commands": [
{
"Cmd": "SetSystemTime",
"NewTime": "2017-09-19T12:34:56"
}
]
}
You have to set to the current UTC (Coordinated Universal Time) time.
Change log file upload configuration
You can activate or deactivate the upload of log files via the file with
the command on a USB stick. This reduces the
amount of data that is stored for a environment on the backend side and reduces the mobile
data costs for uploading data to Industrial IoT.
ConBox_Commands.json
ChangeLogFileUploadConfiguration
Troubleshooting
7.1 Troubleshooting
MindConnect Nano
System Manual 7/2023103

Table of Contents

Other manuals for Siemens MindConnect Nano

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MindConnect Nano and is the answer not in the manual?

Siemens MindConnect Nano Specifications

General IconGeneral
BrandSiemens
ModelMindConnect Nano
CategoryGateway
LanguageEnglish

Related product manuals