Startup Nur für den internen Gebrauch
P31003-E8400-A100-3-7620
3-4 Service Manual
Te l e p h on e Tes t s
3.6 Telephone Tests
Accessing the Telephone Test
The telephone test is started by pressing the "service key" and entering the "code number".
● Tests run for approx. 10 s. These are followed by a timeout.
● Tests can be stopped at any time by pressing the pound key .
optiPoint 500 Models with Display (economy, basic, standard and advance)
● You can browse and display individual tests in the Service menu.
● Display individual call numbers
● Activate LEDs and calls.
● Display showing if power supply is sufficient
– if sufficient power is being supplied, a light grey pixel pattern is visible
Code
number
Menu text Action after pressing OK
91 LED Start the LED test
92 Screen Start the screen tests
93 Keys Start the key test
94 Audio Go to the audio test/submenu
941 Speaker Test the speaker volume (7 levels)
942 Handset Test the handset volume (7 levels)
943 Ringer volume Change the ringer volume (7 levels)
944 Ringer pitch Change the ringer pitch (7 levels)
945 Alerting tone Change the volume of the alerting tone (7 levels)
946 Speakerphone mode Handsfree function (3 levels):
normal, loud, noisy room
940 Back Return to the audio test
95 Asset ID Display the asset ID
96 Software version Display the telephone SW version
97 Feeding range Start the feeding range test
90 Back Return to the telephone test
Table 3-1 Telephone test for HiPath 4000/Hicom 300 H