P31003-E8400-A100-3-7620
Service Manual
5-11
Nur für den internen Gebrauch
Option Adapters and Ports
optiPoint 500 Phone Adapter (Host/Client)
5.5 optiPoint 500 Phone Adapter (Host/Client)
The phone adapter facilitates the connection of a second U
P0/E
terminal with its own power
supply unit (client) for using the second B-channel.
The connected client phone can send and receive calls independently of the host telephone’s
connection status.
Functional Description
The phone adapter has a single MW6 modular connector with 4 pins that supply the interface
for the client phone.
Restriction:
Range limited to 100 meters.
>
If you need to extend the range or operate additional options a local power supply
unit is required (see chapter „Local Power Supply Unit“.
MW6/6
Pin 1Pin 2Pin 3Pin 4Pin 5Pin 6
NC AUX - UP
0
-UP
0
+AUX + NC
6 5 4 3 2 1
RJ11