P31003-E8400-A100-3-7620
Service Manual
5-5
Nur für den internen Gebrauch
Option Adapters and Ports
optiPoint 500 acoustic adapter
Ringing, alerting, and key tones are switched to the basic speaker (and not to the external
speaker port).
You can use the volume keys on the telephone to adjust the volume level of both the inter-
nal and external speakers.
You can also use the volume control on the external amplifier to adjust the volume of the
external speaker.
Pin assignments, Desk Microphone and External Speaker: MW 8/8
External Speaker:
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8
+U GND NF Sens LS_SENS LSP NC DGND
Internal resistance: 0 ohms; 10 µF
Level (with PCM -20dBm): -4.8 dBm (at volume level 8; 0.775 V = 0 dBm)
Sense lead to GND: Int. speaker deactivated, active for ringer only
1 2 3 4 5 6 7 8
RJ45
Y cable MW8/8
for connecting
speaker and mi-
crophone
Floating contact
(MW6/6)
Headset MW8/8