Parameterization
5.3 Configuration parameters of the RF180C
RF180C communication module
36 Operating Instructions, 12/2012, J31069-D0177-U001-A6-7618
4. Click the "LED flashes" button.
On the selected IO device both "Link" and "RX/TX" LEDs flash on the connection block.
5. Click the "LED flashes" button to stop the flashing.
5.3 Configuration parameters of the RF180C
The GSDML file contains four parameters relevant to RFID that must be set. They are set by
selecting the "Object properties" for slot 0 of the RF180C in HW Config.
The parameters are described in the "Function Manual FB 45
(http://support.automation.siemens.
com/WW/view/en/21738808)". The table below shows
the possible settings:
Table 5- 1 Setting of RFID-relevant parameters
Parameter name Value Note
FB 45 Default
FB 55 -
USER_Mode
RFID standard profile -
MOBY I / E standard addressing -
MOBY I file handler With later firmware version
MOBY U / D / RF200 / RF300 /
RF600 standard addressing
Default
MOBY U file handler With later firmware version
MOBY_Mode
RF300 Filehandler -
19.2 k baud -
57.6 k baud -
Baud rate RF200 / RF300 /
RF600 / MOBY U/D
115.2 k baud Default
None Standard diagnostics only
Hard errors Hardware-related messages
only
Diagnostics with diagnostics
messages (see section
"Diagnostics (Page 49)")
Hard / soft errors All messages
None Default
Channel 1 -
Suppression of error LED
during startup
Channel 2 -