Technical Specifications
5
This section provides important technical specifications related to the device.
5.1 Power Supply Specifications
Note
Use the internal fuse rating to determine the size of the external circuit breaker/fuse.
Note
When determining cable lengths, make sure the minimum input voltage for the
power supply is provided at the power source.
Input RangePower
Supply Type
Min Max
Internal
Fuse Rating
Maximum Power
Consumption
24 VDC (Single) 13 VDC 36 VDC 10 A 62 W
48 VDC (Single) 38 VDC 72 VDC 5 A 59 W
98 VDC 300 VDCHigh Voltage
AC/DC
88 VAC
a
264 VAC
a
3.15 A 66 W
a
Rated at frequency range 47Hz - 63Hz.
5.2 Failsafe Alarm Relay Specifications
NOTICE
The alarm switching voltage must be greater than the Safety Extra Low-Voltage
(SELV) to meet safety requirements.
Parameter Value (Resistive Load)
Maximum Switching Voltage
250 VAC
30 VDC
Rated Switching Current
2 A @ 250 VAC
2 A @ 30 VDC
0.15 A @ 125 VDC
Maximum Switching Capacity
150 W
500 VA
RUGGEDCOM RSG2488
Installation Manual, 07/2021, C79000-G8976-1048-11
31

Other manuals for Siemens RUGGEDCOM RSG2488

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM RSG2488 and is the answer not in the manual?

Siemens RUGGEDCOM RSG2488 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM RSG2488
CategorySwitch
LanguageEnglish

Related product manuals