Technical specifications
8.1 SCALANCE X414-3E and X408-2 - technical specifications
SCALANCE X-400
Operating Instructions, 06/2015, C79000-G8976-C186-12
141
Cascading depth
SCALANCE X414-3E
SCALANCE X408-2
Linear/star structure Any (only depending on signal
propagation time)
Any (only depending on signal
propagation time)
Ring with redundancy manager
in HRP mode
50 (for reconfiguration time <
0.3 seconds)
50 (for reconfiguration time <
0.3 seconds)
Switching properties
SCALANCE X414-3E
SCALANCE X408-2
Max. number of learnable ad-
dresses
8000 8000
Aging time (default)
40 s
40 s
Switching technique
Store and forward
Store and forward
Latency (store and forward time) 5 µs 5 µs
(10 µs when changing from
gigabit to Fast Ethernet or vice
versa)
Full wire speed switching
Number of frames
At a frame length of (in bytes):
at 100 Mbps
at 1000 Mbps
148810
1488095
64
84459
844595
128
45290
452899
256
23496
234962
512
11973
119732
1024
9615
96154
1280
8127
81274
1518
Note
The IE Switches X
-400 support full wire speed switching complying with IEEE 802.3 on all
ports.
The number of packets depends on the packet length according to the IEEE802.3 standard.

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals