Safety notices on use in hazardous areas
General safety notices relating to protection against explosion
WARNING
Unsuitable cables or connectors
Risk of explosion in hazardous areas
Only use connectors that meet the requirements of the relevant type of protection.
If necessary, tighten the connector screw connections, device fastening screws, grounding
screws, etc. according to the speci󹪝ed torques.
Close unused cable openings for electrical connections.
Check the cables for a tight 󹪝t after installation.
WARNING
Lack of equipotential bonding
If there is no equipotential bonding in hazardous areas, there is a risk of explosion due to
equalizing current or ignition sparks.
Ensure that equipotential bonding is available for the device.
WARNING
Unprotected cable ends
There is a risk of explosion due to unprotected cable ends in hazardous areas.
Protect unused cable ends according to IEC/EN 60079-14.
WARNING
Improper installation of shielded cables
There is a risk of explosion due to equalizing currents between the hazardous area and the non-
hazardous area.
Ground shielded cables that cross hazardous areas at one end only.
Lay a potential equalization conductor when grounding at both ends.
WARNING
Insu󹪟cient isolation of intrinsically safe and non-intrinsically safe circuits
Risk of explosion in hazardous areas
When connecting intrinsically safe and non-intrinsically safe circuits, ensure that the
galvanic isolation is performed properly in compliance with local regulations (e.g. IEC
60079-14).
Observe the device approvals applicable for your country.
Connecting up
6.1 Safety when connecting up
SCALANCE XRH-300/XRM-300
52 Equipment Manual, 10/2022, C79000-G8976-C546-01