5. Connect a client PC to an Ethernet port of the device via an Ethernet cable.
Note
In this state, only direct communication with the device is possible. Data tra󹪟c is not
forwarded across ports.
6. Assign an IP address to the device using DHCP or the SINEC PNI.
7. Open a Windows command prompt and change to the directory where the 󹪝le with the new
󹪝rmware is located and then execute the following command :
tftp -i <IP address> put <firmware file>
Note
You can enable TFTP in Microsoft Windows as follows:
"Control Panel > Programs and Features > Turn Windows features on or o󹪜 > TFTP Client".
Once the 󹪝rmware has been transferred completely to the device and validated, the device
restarts. This may take a few minutes.
Troubleshooting
8.3 Load a 󹪝rmware 󹪝le via TFTP
SCALANCE XRH-300/XRM-300
80 Equipment Manual, 10/2022, C79000-G8976-C546-01