EasyManua.ls Logo

Siemens SCALANCE XRH-300

Siemens SCALANCE XRH-300
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical speci󹪝cations
Ambient temperature
2)
Property Startup at -25 °C
With LAN operation with RJ45 plug
Up to 2000 m above sea level
During operation in horizontal installation position:
-25 °C to +60 °C
When operating with plug-in trans‐
ceivers of the types:
[-] Standard version
LD except SFP993-1LD
SFP993-1LD up to max. 4 units
Up to 2000 m above sea level
During operation in horizontal installation position:
-25 °C to +60 °C
When operating with SFP Transceiv‐
ers of the type:
SFP993-1LD as of 5 units
Up to 2000 m above sea level
During operation in horizontal installation position:
-25 ℃ to +55 ℃
When operating with plug-in trans‐
ceivers of the types
3)
:
SFP992-1+
LD+
LH
LH+
ELH
ELH200
BXMR
BXMT
BX10T
BX10R
Up to 2000 m above sea level
During operation in horizontal installation position:
-25 °C to +50 °C
With operation between 2000 m
and 3000 m above sea level
The maximum ambient temperature is reduced by
5 °C
4)
During storage -40 °C to +85 °C
During transportation -40 °C to +85 °C
Relative humidity During operation at 25 ℃ ≤ 95% without condensation
Housing, dimensions and weight
Design Rack
Housing material Metal
Degree of protection IP20
5)
Dimensions (W x H x D) 446 x 43.5 x 384.8 mm (1 height unit)
Weight Device version with one power sup‐
ply unit
8200 g
Device version with two power sup‐
ply units
8400 g
Installation options
19" rack mounting
Four-point mounting
Mounting restriction Operation with a DC terminal block only within a control cabinet
Technical speci󹪝cations
9.2 SCALANCE XRM334 with 12 SFP/SFP+ slots
SCALANCE XRH-300/XRM-300
92 Equipment Manual, 10/2022, C79000-G8976-C546-01

Table of Contents

Related product manuals