Loading...
Mounting the tripped signaling switch S24
Mounting the remot
e reset magnet RR
Connection and commissioning
5.3Mounting accessories
3VA27 molded case cir
cuit break
ers & 3WL10 air circuit break
ers
Equipment Manual, 10/2023, L1V30499596002-03
175
175
177
Table of Contents
Main Page
Table of Contents
4
Introduction
10
About this Documentation
10
Product-Specific Information
10
Target Readers
10
Technical Support
10
Reference Documents
11
Advanced Training Courses
11
Safety Instructions
12
Open Source Software
13
Transport
14
Description
16
Current-Carrying 3WL10 Circuit Breakers
16
Current-Limiting 3VA27 Molded Case Circuit Breakers
16
Advantages of the Platform Approach
16
Overview - Applications and Portfolio
17
Basic Properties of the Circuit Breaker (3WL10 / 3VA27)
17
Applications
21
Possible Uses and Portfolio
23
Portfolio of 3WL10 Air Circuit Breakers
25
Portfolio of 3VA27 Molded Case Circuit Breakers
26
Electronic Trip Unit (ETU)
26
3VA27 / 3WL10 for Motor Protection Applications
27
Basic Unit
31
Product and Mounting Versions
31
Design of the Circuit Breaker
32
Withdrawable Breaker
32
Technical Overview
35
Circuit Breaker Identification
40
Electronic Trip Unit ETU
44
Description of Functions
44
Selectivity
47
Design of the Electronic Trip Units
49
Electronic Trip Units of the 3-Series
49
Electronic Trip Units of the 6-Series
50
Characteristics of the ETU
52
Characteristic Curves
61
Features and Options
64
Parameters of the Trip Units
67
Metering Functions
77
Communication
81
Accessories Overview
84
Accessories
86
Accessories for Connection and Insulation
88
Insulating Measures
88
Connections of the Fixed Breaker Version
90
Connections of the Withdrawable Breaker Version
93
Electromechanical Accessories
95
Auxiliary Releases for 3VA27 / 3WL10
95
Accessories for Circuit Breakers
98
Auxiliary, Alarm, and Signaling Switches
101
Accessories for Communication Link, Remote Switching, and I/O Modules
107
Rotary Operators
110
Door Mounted Rotary Operator
110
Front Mounted Rotary Operator
112
External Accessories
113
External Digital I/O Module IOM300
113
Description
113
External Current Transformers
114
Rogowski CT solo External Neutral
114
External CT for Grounding Conductors of the Main Power Supply (Grounded Transformer Star Point) G_Ret Using the Ground Fault Return
115
Summation Current Transformer Rc CT
116
Locking and Interlocking
116
Support for Floor Fixation (Fixed Breaker)
124
Breaker Data Adapters and Test Devices
125
Overview
125
TD310 Activation & Trip Box
126
TD410 Breaker Data Adapter
126
TD420 Test Device
127
Application Planning
130
Types of Installation and Installation Locations
130
Mounting Position
130
Degree of Protection
133
Power Loss
133
Ambient Conditions
133
Current Reduction
134
Current Reduction Depending on the Ambient Temperature on the 3WL10
134
Current Reduction Depending on the Ambient Temperature on the 3VA27
135
Use in IT Systems
138
Electromagnetic Compatibility
139
Installation in the Switchboard
139
Power Supply, Grounding, and Connection
141
Power Supply, Grounding, and Connection
143
Isolating Distances and Insulating Equipment
148
Armature Plates
150
Communication Planning
151
Connection and Commissioning
154
Safety Regulations and Information
154
Mounting and Connecting the Device
155
Tightening Torques at a Glance
155
Mounting Connections
156
Fixed Breaker: Installing the Circuit Breaker
163
Withdrawable Breaker: Installing the Circuit Breaker / Guide Frame
165
Mounting Accessories
168
Installing Accessories
168
Examples of Mounting Internal Accessories
175
Function Test of the ETU
178
Commissioning
179
General Tests
179
Procedure for Testing the Accessories
181
Final Tests
183
Operation
184
Opening and Closing
184
Entering Parameters
186
Racking the Circuit Breaker (Withdrawable Breaker)
189
Alarms
192
Troubleshooting
197
Service and Maintenance
200
Safety Regulations
200
Tests During Inspections and after Tripping
201
Maintenance Intervals
201
Enclosure, Terminals, and Control Panel
202
Checking and Cleaning the Housing
202
Basic Unit and Accessories
203
Removing the Front Plate and Accessories
203
Cleaning and Lubricating the Tripping Mechanism
204
Inspecting the Accessories
204
Testing the ETU
205
Final Tests
205
Technical Specifications
208
Technical Data 3WL10
208
Technical Specifications - 3VA27
208
Dimension Drawings
210
Fixed-Mounted Breaker
210
Circuit Breaker Without Connections
210
Front Terminals for Main Circuit Connection
211
Front Terminals for Main Circuit Connection, Extended
212
Front Connection Bars, Broadened
213
Horizontally / Vertically Orientable Rear Connection
214
Circular Conductor Terminal, Adapter 4X240
216
Switchboard Panel, Hole and Drilling Templates, Fixed Breaker
217
Fixed-Mounted Version with Mounting Support
220
Withdrawable Breaker
221
Circuit Breaker Without Connections
221
Horizontally / Vertically Orientable Rear Terminal for Main Circuit Connection
222
Copper/Aluminum Cable Connection Bar
223
Front Extended Terminal
224
Front Connection Bars, Broadened
225
Rear Connection Bars, Broadened
226
Switchboard Panel, Hole and Drilling Templates, Withdrawable Breaker
227
Further Dimension Drawings
230
Phase Barrier
230
Door Covers
230
Terminal Cover
231
Circuit Diagrams
232
Circuit Diagrams of Accessories
239
Tripped Signaling Switch (S24)
239
Spring Charging Motor (MO), Spring Charged Signaling Switch (S21), Remote Reset Magnet (RR)
239
Tripped Signaling Switch, Toggle Operating Mechanism MCCB (TAS)
240
Leading Changeover Switch (S26)
240
CT for Grounded Transformer Star Point (G_Ret)
241
Summation Current Transformer (Rc CT)
241
CB Bus Module
242
External I/O Module IOM300
243
External Current Transformer for N Conductor, for 3-Pole Circuit Breakers Only
244
Tripped Signaling Switch Via Auxiliary Release (S25)
245
Ready-To-Close Signaling Switch (RTC)
245
Undervoltage Release / Shunt Release (UVR / ST2)
245
Time-Delay Device for UVR (External Monitoring of UVR Can be Mounted on the DIN Rail)
246
Closing Coil (CC) / Shunt Release (ST) / Actuator Module (COM ACT)
246
Auxiliary Switch aux
247
Auxiliary Switch aux 15, External
248
Optional Voltage Input, External Neutral for the Metering Function of a 3-Pole Circuit Breaker
248
Position Signaling Switch PSS for Guide Frame
249
Appendix
250
The Article Number System
250
Menu Structure of the Etus of the 6-Series
255
ESD Guidelines
266
Electrostatic Sensitive Devices (ESD)
266
Other manuals for Siemens SENTRON 3WL10
Manual
290 pages
Related product manuals
Siemens SENTRON 3WL
27 pages
Siemens SENTRON 3WA
82 pages
Siemens SENTRON 3WA1
576 pages
Siemens SENTRON 3WA Air
50 pages
Siemens Sentron 3VA
492 pages
Siemens SENTRON 3VA2
676 pages
Siemens SENTRON 3VA1
676 pages
Siemens SENTRON 3VA27
290 pages
Siemens Sentron WL
360 pages
Siemens SENTRON VL160X
3 pages
Siemens SENTRON VL Series
10 pages
Sensitrip III Sentron Series
5 pages