Using the SSI_Absolute_Encoder technology object
4.4 Configuring SSI_Absolute_Encoder
Counting, measurement and position detection
148 Function Manual, 12/2017, A5E32009889-AG
Function of a digital output
(Page 48) in operating mode "Use
position value (SSI absolute val-
ue) as reference"
Meaning
Additional option-specific pa-
rameters
After set command from CPU until
comparison value
When a set command is sent from the CPU, the
respective digital output is active for the assigned
direction of the position value change until the posi-
tion value is equal to the comparison value or has
fallen below or exceeded it.
Comparison value 0
Comparison value 1
Count direction
Hysteresis (in increments)
Use by user program The respective digital output can be switched by
the CPU via the control interface (Page 43).
Note
You can only select the "Between comparison value
0 and 1" function for digital output DQ1
and only if you have selected the "Use by user program"
function for digital output DQ0.
Function of a digital output
(Page 52) in operating mode
"Use measured value as refer-
ence"
Meaning
Additional option-specific pa-
rameters
Measured value >= comparison
value
(default)
The respective digital output is active if the measured
value is greater than or equal to the comparison val-
ue.
Comparison value 0
Comparison value 1
Measured value <= comparison
value
The respective digital output is active if the measured
value is less than or equal to the comparison value.
Comparison value 0
Comparison value 1
Between comparison value 0 and
1
The digital output DQ1 is active if:
Comparison value 0 <= measured value <= compari-
son value 1
Comparison value 0
Comparison value 1
Not between comparison value 0
and 1
The digital output DQ1 is active if:
Comparison value 1 <= measured value <= compari-
son value 0
Comparison value 0
Comparison value 1
Use by user program The respective digital output can be switched by the
CPU via the control interface (Page 43).
Note
You can select the "Between comparison value
0 and 1" and "Not between comparison
value
0 and 1" functions only for
digital output DQ1 and only if you have selected the "Use by
user program" function for digital output DQ0.