Using the SSI_Absolute_Encoder technology object
4.5 Programming the SSI_Absolute_Encoder
Counting, measurement and position detection
Function Manual, 12/2017, A5E32009889-AG
165
4.5.7
Static tags SSI_Absolute_Encoder
Tag
Data type
Default
Access
Description
NewReferenceValue0 DINT L#0 Write New comparison value 0 in operating mode
"Use position value (SSI absolute value) as
reference"
NewReferenceValue1 DINT L#10 Write New comparison value 1 in operating mode
"Use position value (SSI absolute value) as
reference"
NewReferenceValue0_M REAL L#0.0 Write New comparison value 0 in operating mode
"Use measured value as reference"
NewReferenceValue1_M REAL L#10.0 Write New comparison value 1 in operating mode
"Use measured value as reference"
CurReferenceValue0 DINT L#0 Read Current comparison value 0 in operating mode
"Use position value (SSI absolute value) as
reference"
CurReferenceValue1 DINT L#10 Read Current comparison value 1 in operating mode
"Use position value (SSI absolute value) as
reference"
CurReferenceValue0_M REAL L#0.0 Read Current comparison value 0 in operating mode
"Use measured value as reference"
CurReferenceValue1_M REAL L#10.0 Read Current comparison value 1 in operating mode
"Use measured value as reference"
AdditionalErrorID DWORD W#16#0000 Read Error information of an internal instruction,
e.g.,RDREC
UserCmdFlags
STRUCT
-
SetReferenceValue0 BOOL FALSE Write Set comparison value 0
SetReferenceValue1
BOOL
FALSE
Write
Set comparison value 1
SetDQ0 BOOL FALSE Write Set digital output DQ0
SetDQ1
BOOL
FALSE
Write
Set digital output DQ1
ManualCtrlDQ0 BOOL FALSE Write Enable setting of digital output DQ0.
TRUE: SetDQ0 sets DQ0
1
FALSE: Setting not enabled
ManualCtrlDQ1 BOOL FALSE Write Enable setting of digital output DQ1:
TRUE: SetDQ1 sets DQ1
1
FALSE: Setting not enabled
UserStatusFlags
STRUCT
-
StatusDI0
BOOL
FALSE
Read
Current status of digital input DI0
StatusDI1
BOOL
FALSE
Read
Current status of digital input DI1
StatusDQ0
BOOL
FALSE
Read
Current status of digital output DQ0
StatusDQ1
BOOL
FALSE
Read
Current status of digital output DQ1
1
The instruction sets the TM_CTRL_DQm bit to FALSE. in the control interface of the module. The static tag SetDQm
acts on the control bit SET_DQm.