The basics of counting, measurement and position detection
2.2 Basics of counting, measuring and position input (TM Count, TM PosInput, Compact CPU)
Counting, measurement and position detection
Function Manual, 12/2017, A5E32009889-AG
49
Setting between comparison value and low limit
The low limit corresponds to the position value "0".
The digital output is set to 1 if:
0 <= position value <= comparison value
The comparison event is independent of the direction of the position value change.
Setting between comparison value 0 and comparison value 1
The comparison event can be configured for the digital output DQ1 if "Use by user program"
has been configured for the digital output DQ0.
DQ1 is set to 1 if:
Comparison value 0 <= position value <= comparison value 1
The comparison event is independent of the direction of the position value change.