Technical Specifications
B-3
SIMATIC Field PG Manual
A5E00075760-04
Ambient conditions
Temperature
operation
storage/transport
tested to DIN IEC 60068-2-1, DIN IEC 60068-2-2
+5
o
C to +40
o
C *(no condensation permitted)
– 20
o
C to +60
o
C**(no condensation permitted)
( *10
o
C/h, ** 20
o
C/h)
Relative humidity
operation
storage/transport
tested to DIN IEC 60068-2-3, 60068–2–30, 60068–2–14
5% to 80% at 25
o
C (no condensation permitted)
5% to 95% at 25
o
C (no condensation permitted)
Mechanical specifications
Vibration
operation *)
transport
tested to DIN IEC 60068-2-6
10 to 58Hz; amplitude 0.035 mm
58 to 500Hz; acceleration 5 m/s
2
5 to 9Hz; amplitude 3.5 mm
9 to 500Hz; acceleration 9.8 m/s
2
Shock
operation *)
storage
tested to DIN IEC 60068-2-29
half–sine: 50 m/s
2
, 30 ms, 100 shocks
half–sine: 250 m/s
2
, 6 ms, 1,000 shocks
Motherboard
Integrated processor Intel Mobile PentiumIII / Celeron (see BIOS)
Level 2 cache first level: 16 Kbytes data, 16 Kbytes program
second level: 128/256 Kbytes (processor dependent)
Main memory 64 Mbytes expandable to max. 512 Mbytes,
(64-bit SO DIMM) (for memory expansion see BIOS)
Drives
Floppy disk drive Standard Floppy disk drive (1.44 Mbytes), Super disk
LS120 or Super disk LS240 drive (see BIOS)
Hard disk drive 2.5” (capacity see BIOS)
Hard disk/CD-ROM controller IDE (ATA)-33
Optical Drive CD ROM (24x) or
DVD ROM (24x CD ROM, 8x DVD) or
DVD ROM/CD RW (24x CD ROM, 8x DVD, 8x CD RW)
(equipment see BIOS)
Graphics
Controller integrated in Intel Chipset FW82 815 EM
Graphics memory Dynamic Video Memory Technology
Resolutions / frequencies / colors CRT: up to 1280x1024 / 85 Hz / 4 mio. colors or
1600 x 1200 / 75 Hz 265k colors
* Burning operation with DVD-ROM/CD-RW permissible only in undisturbed enviromment.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simatic Field PG and is the answer not in the manual?

Siemens Simatic Field PG Specifications

General IconGeneral
BrandSiemens
ModelSimatic Field PG
CategoryMotherboard
LanguageEnglish

Related product manuals