Commissioning the device
4.3 Parameter assignment for Comfort Panel
Comfort Panels
Operating Instructions, 07/2017, A5E36770603-AB
101
Activating memory management
Note
Memory management
If you do not activate memory manage
ment, undefined states can occur during the runtime
of the project.
Requirement
The Control Panel is open.
Procedure
Proceed as follows:
1. Open the "OP Properties" dialog using the "OP" icon.
2. Change to the "Memory Monitoring" tab.
3. If you want to enable memory management, select "Shut down HMI Runtime...".
4. Confirm your entries with "OK".
Result
Memory management is activated. An open project is closed under these circumstances:
Insufficient RAM
RAM needs to be reorganized
An alarm is then triggered on the HMI device. Restart the project on the HMI device.