Commissioning the device
4.3 Parameter assignment for Comfort Panel
Comfort Panels
Operating Instructions, 07/2017, A5E36770603-AB
145
– Alarms of type "Error" with option:
Icon
Status
Alarm
Meaning
Upgrade Runtime upgrade
Runtime version on the HMI device is older
than the Runtime version of the project,
versions are incompatible, upgrade of
Runtime version on the HMI device is
required.
Upgrade Firmware upgrade
Firmware version on the HMI device is older
than the firmware version of the project,
versions are incompatible, upgrade of
firmware on the HMI device is required.
Downgrade Runtime downgrade
Runtime version on the HMI device is newer
than the Runtime version of the project,
versions are incompatible, downgrade of
Runtime version on the HMI device is
required.
Downgrade Firmware downgrade
Firmware version on the HMI device is newer
than the firmware version of the project,
versions are incompatible, downgrade of
firmware on the HMI device is optional.
Download Runtime download
There is no Runtime software on the HMI
device, e.g. after update of the operating
system. Runtime software must be
downloaded.
NOTICE
Data loss
If you enable the "Firmware upgrade" or "Firmware downgrade" option, the operating
system of the HMI device will be updated. All data on the HMI device, including the
HMI device password, is deleted in the process. Settings in the Start Center are
retained. License keys are backed up to the external storage medium before the
operating system update.
Back up your data before the load operation, if necessary.
The project can be loaded into the HMI device if no "Error..."-type alarms occur or if all
"Upgrade/Downgrade" options were enabled for the "Error..."-type alarms.
6. Use "Load" to transfer the project data with the selected options to the HMI device.
The new project starts on the HMI device after the load operation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC HMI TP700 Comfort and is the answer not in the manual?

Siemens SIMATIC HMI TP700 Comfort Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC HMI TP700 Comfort
CategoryControl Panel
LanguageEnglish

Related product manuals