6 Programmed Communication Connections
A-164
S7-CPs for Industrial Ethernet Configuring and Commissioning
Release 01/2007
C79000-G8976-C182-07
6.3 Configuration Data Block
Meaning
The configuration data block (CONF_DB) contains all the connection data and
configuration data (IP address, subnet mask, default router, NTP time server and
other parameters) for an Ethernet CP. The configuration data block is transferred
to the CP with function block FB55.
Block and Data Structure
The graphic below shows the following:
Structure resulting from parameter fields and subfields
- The connections and specific system data are is described by an identically
structured parameter field.
- Individual parameters are characterized by subfields.
Offset range
The CONF_DB can start at any point within a data block as specified by an
offset range.
Configuration data
block
Connection 1
Connection n *)
Connection 2
System data for CP
DB identifier
Parameter field for system data (CP
networking) and connections
Subfield 1
Subfield n
Subfield 2
ID (for system data = 0)
Type
Number of subfields
Individual
parameters
Subfield
Offset range 0..n
CONF_DB
Subfield types are
described below in
Section 6.6
Parameter fields are
described below in
Sections 6.4 and 6.5

Table of Contents

Other manuals for Siemens SIMATIC NET S7-300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET S7-300 and is the answer not in the manual?

Siemens SIMATIC NET S7-300 Specifications

General IconGeneral
Product Type DesignationSIMATIC NET S7-300
MountingDIN rail mounting
Protection ClassIP20
CPU ModelsVarious models available (e.g., CPU 312, CPU 314)
Communication InterfacesMPI, PROFIBUS DP
Power Supply24 V DC power supply required. Different power supply modules available.
I/O ModulesDigital input modules, digital output modules, analog input modules, analog output modules
ProgrammingSTEP 7 software
Supply Voltage24V DC or 120/230V AC (depending on model)
Digital InputsAvailable via digital input modules
Digital OutputsAvailable via digital output modules
Analog InputsAvailable via analog input modules
Analog OutputsAvailable via analog output modules
Communication FunctionsMPI, PROFIBUS DP, Ethernet (depending on model)
ProtocolsMPI, PROFIBUS DP, TCP/IP (depending on model)
Operating Temperature0°C to 60°C
Storage Temperature70 °C
MemoryDepends on CPU model (e.g., 32 KB to 1.5 MB)