1 Communication via Ethernet CPs in S7 Stations
A-25
S7-CPs for Industrial Ethernet Configuring and Commissioning
Release 01/2007
C79000-G8976-C182-07
1.3.1 PG Communication with STEP 7 over Industrial Ethernet
Requirements for PG Communication
PG communication is possible when the following requirements are met:
An Ethernet CP is installed in the PG or engineering station or there is a
modem/ISDN interface for remote access.
The Ethernet CP must have an address (default MAC address or set the IP
address).
Networking the PG / Engineering Station
Depending on the configuration of the PG or Engineering Station, the following two
situations are possible when using PG communication:
PG / Engineering Station in the Configured Mode
If you select this configuration when you commission the PG / engineering
station, the interfaces of the communication modules you are using are already
known. The option in “Set PG/PC Interface” is automatically set to
“PC-internal”.
Once you have downloaded this configuration to your PG / engineering station,
you can exchange PG functions with the accessible nodes in the network with
STEP 7 without requiring any further settings.
PG / Engineering Station in PG Operation
If your PG or engineering station is configured for this mode, you must specify the
interface on the PG or engineering station explicitly with “Set PG/PC Interface”.
Follow the steps outlined below:
1. Open the “Set PG/PC Interface” dialog box in the Windows Control Panel.
2. Set the PG/PC interface according to the CPs available on your PG and
according to the bus attachment (interface parameter assignment used).
For more detailed information on the topic of PG operation and engineering station,
refer to /4/.

Table of Contents

Other manuals for Siemens SIMATIC NET S7-300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET S7-300 and is the answer not in the manual?

Siemens SIMATIC NET S7-300 Specifications

General IconGeneral
Product Type DesignationSIMATIC NET S7-300
MountingDIN rail mounting
Protection ClassIP20
CPU ModelsVarious models available (e.g., CPU 312, CPU 314)
Communication InterfacesMPI, PROFIBUS DP
Power Supply24 V DC power supply required. Different power supply modules available.
I/O ModulesDigital input modules, digital output modules, analog input modules, analog output modules
ProgrammingSTEP 7 software
Supply Voltage24V DC or 120/230V AC (depending on model)
Digital InputsAvailable via digital input modules
Digital OutputsAvailable via digital output modules
Analog InputsAvailable via analog input modules
Analog OutputsAvailable via analog output modules
Communication FunctionsMPI, PROFIBUS DP, Ethernet (depending on model)
ProtocolsMPI, PROFIBUS DP, TCP/IP (depending on model)
Operating Temperature0°C to 60°C
Storage Temperature70 °C
MemoryDepends on CPU model (e.g., 32 KB to 1.5 MB)

Related product manuals