EasyManua.ls Logo

Siemens Simatic S7-1500R - Page 57

Siemens Simatic S7-1500R
393 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Feature
You need the 1518HF-4 PN CPUs. With the integrated F-functionality, you evaluate the
emergency stop buttons via PROFIsafe.
Solution
If one of the CPUs fails (loss of redundancy), the S7‑1500HF redundant system switches from
the RUN-Redundant system state to the RUN-Solo system state. The HF-system reduces the
probability of an F-STOP being triggered on failure of a CPU.
You evaluate the emergency stop buttons at the track switch positions and transshipment
facilities via fail-safe modules in the ET 200SP distributed I/O system. If a dangerous situation
or a baggage jam occurs, an employee presses the emergency stop button.
Result: The redundant system shuts down the conveyor belt immediately via PROFIsafe.
352),1(7,(
CPU 1518HF-4 PN
Redundancy connections (fiber-optic cables)
ET 200SP IO device for controlling the conveyor belt
PROFINET cables (PROFINET ring)
ET 200SP IO device with fail-safe modules for evaluating the emergency stop buttons
Emergency stop buttons
Figure 4-20Configuration with CPUs 1518HF-4 PN and ET 200SP with fail-safe modules
57
System overview
4.3 S7-1500 R/H-CPUs
S7-1500R/H redundant system
System Manual, 11/2022, A5E41814787-AD

Table of Contents

Other manuals for Siemens Simatic S7-1500R

Related product manuals