SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
P0028 / 1C Max. current
300W
Min Standard Max Unit Data type Effective
0 10.5 21 A C4 immed.
Upper limit, motor current.
Note:
The parameter value can be changed while traversing.
This parameter has a gearbox-dependent factory default.
Maximum values depend on the gear unit ––> see User Manual under the heading ”Gear unit
dependant parameters (factory settings)”
075W
Min Standard Max Unit Data type Effective
0 9 9 A C4 immed.
Upper limit, motor current.
Note:
The parameter value can be changed while traversing.
This parameter has a gearbox-dependent factory default.
Maximum values depend on the gear unit ––> see User Manual under the heading ”Gear unit
dependant parameters (factory settings)”
P0029 / 1D Electronics temperature tolerance time
300W 075W
Min Standard Max Unit Data type Effective
0 120000 2000000 ms T4 immed.
For an electronics overtemperature condition, after this time, the warning is changed to a fault,
i.e. the appropriate response is activated.
Note:
The electronics temperature is displayed using P47.
Input resolution = 10 ms
The parameter value can be changed while traversing.
P0030 / 1E Fault suppression
300W 075W
Min Standard Max Unit Data type Effective
0 0 F Hex I2 immed.
If the bit is set, instead of the appropriate fault, only a warning is output.
Bit 0: Speed controller at its endstop
Bit 1: Start, software limit switch or end, software limit switch
Software limit switches always stop an axis.
Bit 2: Standstill monitoring
Bit 3: Undervoltage of the load current supply (from SW 1.6)
Note:
The parameter value can be changed while traversing.
P0031 / 1F Function terminal 1
300W 075W
Min Standard Max Unit Data type Effective
0 0 793 I2 immed.
The function of the terminal is defined using this parameter:
The following applies from SW 2.0:
The meaning of terminal parameterization depends on the operating mode (P930).