5.6 Parameters for SIMODRIVE POSMO A
5-214
Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
P0034 / 22 Shift factor, test socket 1
300W 075W
Min Standard Max Unit Data type Effective
0 7 F Hex I2 immed.
Shift factor for analog test socket 1.
Note:
Shift factor change of +1 corresponds to doubling the value
Shift factor change by –1 corresponds to halving the value
The parameter value can be changed while traversing.
P0035 / 23 Offset, test socket 1
300W 075W
Min Standard Max Unit Data type Effective
0 80 FF Hex I2 immed.
Offset for analog test socket 1.
Note:
With offset = 80 hex, for ”0” 2.5 V is output.
The parameter value can be changed while traversing.
P0036 / 24 Address, test socket 2
300W 075W
Min Standard Max Unit Data type Effective
0 FC66 FFFFFFFF Hex I4 immed.
Note:
Refer to P33 (address, test socket 1).
P0037 / 25 Shift factor, test socket 2
300W 075W
Min Standard Max Unit Data type Effective
0 0 F Hex I2 immed.
Note:
Refer to P34 (shift factor, test socket 1).
P0038 / 26 Offset, test socket 2
300W 075W
Min Standard Max Unit Data type Effective
0 80 FF Hex I2 immed.
Note:
Refer to P35 (offset, test socket 1).
P0039 / 27 Position setpoint
300W 075W
Min Standard Max Unit Data type Effective
MSR C4 RO
This parameter specifies the position setpoint in the selected unit of measurement.