Biological ambient conditions Suitable in acc. with Class 1B2
Duration Six months for the above-mentioned condi‐
tions.
Special preservation measures are required
for storage periods of 6 months up to a
maximum of two years.
Check the correct state of the motor every six months.
Check the motor for any damage.
Perform any necessary maintenance work.
Check the state of the dehydrating agent and replace when necessary.
Record the preservation work so that all preservation coating can be removed prior to the
commissioning.
Condensation
The following ambient conditions encourage the formation of condensation:
Signi󹪝cant ambient temperature 󹪞uctuations,
Direct sunshine,
High humidity during storage.
Avoid these ambient conditions.
Use a dehydrating agent in the packaging.
Preparation for use
7.2 Bearings
1FK2 Synchronous Motors for SINAMICS S120
134 Con󹪝guration Manual, 02/2022, A5E46927724B AD

Table of Contents