Property Version
Sound pressure level L
pA
(1 m) according to
DIN EN ISO 1680, max. tolerance + 3 dB(A)
1FK2☐03, 1FK2☐04: 55 dB (A);
1FK2☐05, 1FK206: 65 dB (A);
1FK2☐08, 1FK2☐10: 70 dB (A)
Encoder systems, built-in with DRIVE-CLiQ
interface
• AS22DQC absolute encoder 22-bit singleturn
• AM22DQC absolute encoder 22-bit + 12-bit multiturn
Holding brake optionally installed, 24 V DC
Connection Connectors for power and signals, rotatable
Paint nish Anthracite, similar to RAL7016
2.3.3 Torque overview
1FK2 High Dynamic 3 AC 380 ... 480 V
0
.
1P
).
).
).
1P
).
1P
1P
1P
Figure 2-3 1FK210☐ static torques
1FK2 Compact 3 AC 380 ... 480 V
0
.
1P
).
).
).
).
1P
1P
1P
).1P
1P
).1P
Figure 2-4 1FK22☐☐ static torques
Description of the motors
2.3 Technical characteristics and ambient conditions
1FK2 Synchronous Motors for SINAMICS S120
26 Conguration Manual, 02/2022, A5E46927724B AD