EasyManua.ls Logo

Siemens SIMOTICS S-1FK2 - Page 38

Siemens SIMOTICS S-1FK2
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
If the ambient temperature exceeds 40 °C, you need to set the ambient temperature on the
converter.
To do this, select parameter p0613 at the converter, and set the maximum ambient
temperature that occurs.
Parameter r0034 indicates the thermal load of the motor as a percentage. The reading is
in󹪞uenced by the ambient temperature selected in parameter p0613.
You can 󹪝nd more information in the manual for the converter.
Mechanical properties
3.1 Cooling
1FK2 Synchronous Motors for SINAMICS S120
36 Con󹪝guration Manual, 02/2022, A5E46927724B AD

Table of Contents

Other manuals for Siemens SIMOTICS S-1FK2

Related product manuals