Technical data and characteristic curves
6.2 Motor overview / assignment of Motor Modules / power cables
S-1FT7 synchronous motors
144 Configuration Manual, 09/2018, A5E45099423B AA
Table 6- 6 1FT7 Compact natural cooling
Converter: SINAMICS S120 Booksize
Connector size
5)
/
Cable cross-
section
4)
1FT7034-5AK7 2 1 / 4 x 1.5 6SL3120-1TE13-
3 6.3 6FX❑002-5❑N06-
1FT7036-5AK7 3 1 / 4 x 1.5 6SL3120-1TE15-
5 10.8 6FX❑002-5❑N06-
1FT7042-5AF7 3 1 / 4 x 1.5 6SL3120-1TE13-
3 10.9 6FX❑002-5❑N06-
1FT7042-5AK7 3 1 / 4 x 1.5 6SL3120-1TE15-
5 10.4 6FX❑002-5❑N06-
1FT7044-5AF7 5 1 / 4 x 1.5 6SL3120-1TE13-
3 14.8 6FX❑002-5❑N06-
1FT7044-5AK7 5 1 / 4 x 1.5 6SL3120-1TE21-
9 21.9 6FX❑002-5❑N06-
1FT7046-5AF7 7 1 / 4 x 1.5 6SL3120-1TE15-
5 24.5 6FX❑002-5❑N06-
1FT7046-5AH7 7 1 / 4 x 1.5 6SL3120-1TE21-
9 22.4 6FX❑002-5❑N06-
1FT7062-5AF7 6 1 / 4 x 1.5 6SL3120-1TE15-
5 18.7 6FX❑002-5❑N06-
1FT7062-5AK7 6 1 / 4 x 1.5 6SL3120-1TE21-
9 16.4 6FX❑002-5❑N06-
1FT7064-5AF7 9 1 / 4 x 1.5 6SL3120-1TE21-
9 34.7 6FX❑002-5❑N06-
1FT7064-5AK7 9 1 / 4 x 1.5 6SL3120-1TE21-
9 25.3 6FX❑002-5❑N06-
1FT7066-5AF7 12 1 / 4 x 1.5 6SL3120-1TE21-
9 35.2 6FX❑002-5❑N06-
1FT7066-5AH7 12 1 / 4 x 1.5 6SL3120-1TE21-
18 42.8 6FX❑002-5❑N06-
1FT7068-5AF7 15 1 / 4 x 1.5 6SL3120-1TE21-
9 46.0 6FX❑002-5❑N06-
1FT7082-5AC7 13 1 / 4 x 1.5 6SL3120-1TE15-
5 35.0 6FX❑002-5❑N06-
1FT7082-5AF7 13 1 / 4 x 1.5 6SL3120-1TE21-
9 39.8 6FX❑002-5❑N06-
1FT7082-5AH7 13 1 / 4 x 1.5 6SL3120-1TE21-
18 48.0 6FX❑002-5❑N06-
1FT7084-5AC7 20 1 / 4 x 1.5 6SL3120-1TE21-
9 51.0 6FX❑002-5❑N06-
1FT7084-5AF7 20 1 / 4 x 1.5 6SL3120-1TE21-
18 79.5 6FX❑002-5❑N06-
1FT7084-5AH7 20 1.5 / 4 x 2.5 6SL3120-1TE21-
18 60.0 6FX❑002-5❑N36-
1FT7086-5AC7 28 1 / 4 x 1.5 6SL3120-1TE21-
18 120.0 6FX❑002-5❑N06-
1FT7086-5AF7 28 1.5 / 4 x 2.5 6SL3120-1TE21-
18 86.0 6FX❑002-5❑N36-
1FT7086-5AH7 28 1.5 / 4 x 4 6SL3120-1TE23-
30 100 6FX❑002-5❑N46-