ESD guidelines
B.2 Electrostatic charging of individuals
SIMOTION C
190 Operating Instructions, 02/2012
B.2 Electrostatic charging of individuals
Any person who is not conductively connected to the electrical potential of the environment
can accumulate an electrostatic charge.
This figure indicates the maximum electrostatic charges that can accumulate on an operator
when he comes into contact with the indicated materials. These values comply with the
specifications in IEC 801-2.






















          
9ROWDJHLQN9
N9
5HODWLYHDLUKXPLGLW\LQ
6\QWKHWLFPDWHULDO
:RRO
$QWLVWDWLFPDWHULDOHJZRRGRUFRQFUHWH
Figure B-2 Electrostatic voltage that can accumulate on operating personnel