Configuring and installing
4.2 Configuring an installation using SIMOTION C modules
SIMOTION C
80 Operating Instructions, 02/2012
4.2.3 Mounting dimensions of modules
Overview of mounting dimensions
The following table shows the mounting dimensions of modules.
Table 4- 1 Mounting dimensions of modules
Modules Module width Module height Maximum
mounting depth
Power supply PS 307, 2 A
Power supply PS 307, 5 A
Power supply PS 307, 10 A
50 mm
80 mm
200 mm
SIMOTION C 200 mm
Signal modules (SMs) 40 mm
Function modules (FM) 40 mm or 80 mm
Communications processors (CP) 40 mm
125 mm, 185 mm
with shield
connecting element
130 mm or 180 mm
with an open front
cover of the
SIMOTION C
Mounting rail lengths
Depending on the configuration you have chosen, you can use the following mounting rails:
Table 4- 2 Mounting rails
Mounting rail Usable length for modules Comments
160 mm
482.6 mm
530 mm
830 mm
2,000 mm
120 mm
450 mm
480 mm
780 mm
Cut to required length
Mounting holes are provided
Mounting holes are provided
Mounting holes are provided
Mounting holes are provided
Mounting holes must be drilled

Table of Contents

Other manuals for Siemens SIMOTION C230-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION C230-2 and is the answer not in the manual?

Siemens SIMOTION C230-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION C230-2
CategoryController
LanguageEnglish

Related product manuals