5.1 Wiring
SIMOTION C
Operating Instructions, 02/2012
95
SIMOTION C with servo drive (digital connection) via PROFIBUS DP
The figure below shows how the individual components are connected to the SIMOTION C
and the servo drive (digital connection).
)'' )''
'LJLWDOLQSXWV
HJSUREH
([W9
SRZHUVXSSO\
,5
HJ6,02'5,9(XQLYHUVDO
3*3&
5($'<FRQWDFW
03
)URQW
FRQQHFWRU
352),%86'3
FRQQHFWLQJFDEOH
'LJLWDORXWSXWV
3UREH
(WKHUQHWFRQQHFWLQJ
FDEOH
;
6,02'5,9(
6,(0(16
6,027,21&
;
; ;
;;
6,(0(16
;;
;
&
05(6
6723
581
Figure 5-2 Overview of the cable connecting the SIMOTION C to the servo drive (digital connection)
- example

Table of Contents