Supplementary system components
6.5 CBE30 communication board Ethernet
SIMOTION D4x5
Manual, 02/2012
105
6.5.4 Interface description
6.5.4.1 Ethernet interfaces
Features
The X1400 interface has full-duplex 10/100 Mbit Ethernet ports. The module has an
integrated 4-port switch.
Interface features
Table 6- 28 X1400 features
Feature Type
Connector type RJ45 socket
Cable type Industrial Ethernet cable
Maximum cable length 100 m
Dust protection blanking plugs for
sealing unused PROFINET ports
Five blanking plugs contained in the D4x5 scope of delivery.
Blanking plugs (50 pcs):
Order number: 6SL3066-4CA00-0AA0
Pin assignment
Table 6- 29 X1400 interface
Pin Signal name Signal type Meaning
1 TXP Output Ethernet transmit differential signal
2 TXN Output Ethernet transmit differential signal
3 RXP Input Ethernet receive differential signal
4 -- 4 together with 5 via 75 ohm at the 1 nF capacitor
to the shield ground
5 -- 4 together with 5 via 75 ohm at the 1 nF capacitor
to the shield ground
6 RXN Input Ethernet receive differential signal
7 -- 7 together with 8 via 75 ohm at the 1 nF capacitor
to the shield ground
8 -- 7 together with 8 via 75 ohm at the 1 nF capacitor
to the shield ground
Screened
backshell
M_EXT Screen, permanently connected

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION CX32 and is the answer not in the manual?

Siemens SIMOTION CX32 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION CX32
CategoryControl Unit
LanguageEnglish

Related product manuals