Description
1.2 System components
SIMOTION D410-2
16 Manual, 02/2012
DRIVE-CLiQ
SIMOTION D410-2 can communicate via the DRIVE-CLiQ interface with the following
components:
Table 1- 4 Components on DRIVE-CLiQ
Component Function
SINAMICS S120 AC DRIVE
drive units
(with CUA31/CUA32)
... convert speed setpoints into signals for controlling the motor and supply the power
required to operate the motors. The AC DRIVE component PM340 is connected via
CUA31/CUA32. No more than one PM340 can be connected. Power module chassis is
connected via DRIVE-CLiQ.
Note:
Components in booksize format are not supported!
TM15, TM17 High Feature
terminal modules
The terminal modules TM15 and TM17 High Feature are used to implement inputs of
measuring inputs and outputs of cam outputs. In addition, these terminal modules provide
drive-related digital I/Os with short signal delay times.
TM31 terminal module ... enables terminal expansion via DRIVE-CLiQ (additional analog and digital I/Os).
TM41 terminal module ... enables terminal expansion (analog and digital I/Os) and encoder simulation via
DRIVE-CLiQ. The TM41 can be connected to a real axis.
TM54F terminal module ... enables terminal expansion (fail-safe digital I/Os) for controlling the safe motion
monitoring functions of the integrated drive. A TM54F usually not necessary because the
SIMOTION D410-2 has three F-DI and one F-DO.
SMx sensor modules ... enable the acquisition of encoder data from the connected motors via DRIVE-CLiQ.
Motors with
DRIVE-CLiQ interface
... allow simplified commissioning and diagnostics, as the motor and encoder type are
identified automatically.
DMC20/DME20
DRIVE-CLiQ hub
... enables the number of DRIVE-CLiQ interfaces to be increased and the creation of a
point-to-point topology.
Note
Please note that components in booksize format (controller extension, motor modules, line
modules, etc.) as well as SINAMICS G120 (PM2x0) power modules are not supported by
SIMOTION D410-2.
Note
You can find detailed information about components in the SINAMICS S110/S120 family of
products in the SINAMICS S110/S120 manuals.
It is possible that older DRIVE-CLiQ components can no longer be used with
SIMOTION D410-2. You can find detailed information on this in SIMOTION D410-2
Commissioning and Hardware Installation Manual in Section "Migration of SIMOTION D410
to SIMOTION D410-2" at "Permissible combinations".

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D410-2 and is the answer not in the manual?

Siemens SIMOTION D410-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D410-2
CategoryControl Unit
LanguageEnglish

Related product manuals