EasyManuals Logo

Siemens SIMOTION Equipment Manual

Siemens SIMOTION
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
The most important components of the system and their functions are shown below.
Table 2-1 System components
Component Function
SIMOTION D410‑2 … is the central motion control module.
The module contains the programmable SIMOTION runtime of SIMO‐
TION D410‑2 and the SINAMICS S120 drive runtime software.
You can use the integrated high-speed I/Os (onboard I/Os) as:
User-addressable process I/Os
Homing inputs
Fail-safe digital inputs
Fail-safe digital output
Inputs for measuring inputs
Outputs for fast output cams
Analog input
The measuring sockets can output any analog signals.
The DRIVE-CLiQ interface permits a fast connection to the SINAMICS drive
components.
System software The basic functionality of SIMOTION D410‑2 is supplied separately on a Com‐
pactFlash Card containing the following:
SIMOTION runtime (kernel)
Drive software of SINAMICS S120
The CompactFlash card is not included in the scope of delivery.
Power supply (PS) … provides the electronic power supply for SIMOTION D410‑2 (e.g. SITOP
power supply).
PROFIBUS DP
SIMOTION D410-2 can communicate with the following components via the PROFIBUS DP
interface.
Table 2-2 Components on PROFIBUS DP
Component Function
Programming device (PG/PC) con󹪝gures, assigns parameters, programs, and tests using the SIMOTION SCOUT Engi‐
neering System (ES).
SIMATIC HMI device ... is used for operating and monitoring functions. This is not an essential requirement for the
operation of the SIMOTION D410-2.
Other controllers (e.g. SIMO‐
TION or SIMATIC)
… e.g. higher-level controller (plant controller); modular machine concepts with multiple
controllers, distributed across individual machine modules.
Distributed I/O systems
SIMATIC ET 200MP Modular I/O system for cabinet installation and high channel densities in the SIMAT‐
IC S7‑1500 packaging system. SIMATIC ET 200MP permits the shortest bus cycle times and
fastest response time even with large volumes of data.
SIMATIC ET 200M Modular I/O system for cabinet installation and high channel densities in the SIMATIC S7‑300
packaging system.
Description
2.2 System components
SIMOTION D410-2
24 Equipment Manual, 07/2021, A5E33446720B

Table of Contents

Other manuals for Siemens SIMOTION

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION and is the answer not in the manual?

Siemens SIMOTION Specifications

General IconGeneral
Power Supply24 V DC
InterfacesPROFIBUS, PROFINET, Ethernet
Product typeControl Unit
SeriesSIMOTION D
Display OutputVGA