09.02 Parameter List
Siemens AG 6SE7087-6AK85-1AA0
5-9
Rectifier/Regenerating Unit Operating Instructions
PNU
*
: Conf.
Par.
OP1S parameter name
Description
Value range
[phys. unit]
Selection text
Display
Indies
Factory-
setting
See
Modify
(access /
status
P077
*
Factory set. type
Selective factory setting (see Section 4.3.9.1)
The parameter can be modified in the state "MLFB input" (P052=2). There
are two methods for setting the parameters dependent on P077:
1: If a MLFB is not entered (P070=0), once P077 has been entered and
"MLFB input" has been terminated (P052=0), the selected parameter
becomes valid immediately
2: Via the selection "Par.reset" (P052=1 or P970=0), "generate factory
setting" is carried out and the setting of P077 is taken into account. The
values of P070 and P077 will not be changed, but all other parameters
are reset to their factory setting
Parameter values:
0: Factory setting, acc. to "Parameter list", Chapter 5
1: With this setting, the following parameters are initialized differently as
compared to "0"
P554, P555
2: With this setting, the following parameters are initialized differently as
compared to "0"
P554, P555, P565, P566, P567, P575, P588, P607
4: With this setting, the following parameters are initialized differently as
compared to "0"
P554, P555, P565, P566, P575, P588, P607
5: With this setting, the following parameters are initialized differently as
compared to "0"
P486, P554, P555, P561, P565, P566, P567, P572, P575, P583, P587,
P588, 607
6: With this setting, the following parameters are initialized differently as
compared to "0"
P486, P554, P555, P561, P565, P566, P572, P575, P583, P587, P588,
P607
PNU=4DHex; Type=02; Scaling: 1Hex
=
1
0 to 6
RRU
-
0
3/U BR
3/U
r089 Module slot1
Module in slot 1 (left) in the electronics box.
4 = Module CUR
(Designation: RRU=Rectifying Regenerative Unit)
PNU=59Hex; Type=02; Scaling: 1Hex
=
1
4
RRU
-
-
3/ B
https://www.aotewell.com
AoteWell Automation Sales Team
Sales@aotewell.com
AoteWell LTD
Buy Siemens PLC HMI Drives at AoteWell.com
https://www.aotewell.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simovert 6SE70 Series and is the answer not in the manual?

Siemens Simovert 6SE70 Series Specifications

General IconGeneral
BrandSiemens
ModelSimovert 6SE70 Series
CategoryDC Drives
LanguageEnglish

Related product manuals