Contents 09.02
0-4 Siemens AG 6SE7087-6AK85-1AA0
Rectifier/Regenerating Unit Operating Instructions
Page
4 Start-Up ............................................................................................................................... 4-1
4.1 Introduction and handling start-up ....................................................................................... 4-1
4.1.1 Handling the start-up instructions ........................................................................................ 4-1
4.1.2 General explanation of the terminology and functional scope of the
rectifier/regenerating unit ..................................................................................................... 4-1
4.2 Initial start-up ........................................................................................................................ 4-4
4.2.1 Preparatory measures .......................................................................................................... 4-4
4.2.2 Parameterization "Standard application" ............................................................................. 4-5
4.2.3 Parameterization for "Expert application" ............................................................................ 4-7
4.2.5 Simple application examples for connecting process data with connection assignment .... 4-10
4.3 Start-up aids ......................................................................................................................... 4-11
4.3.1 Process data ........................................................................................................................ 4-11
4.3.1.1 Control word (control word 1 and control word 2) ................................................................ 4-11
4.3.1.1.1 Introduction and application example .................................................................................. 4-11
4.3.1.1.2 Overview of the control word (control word 1 and control word 2) ...................................... 4-13
4.3.1.1.3 Selecting the source for control word 1 (bit 0-7) .................................................................. 4-14
4.3.1.1.4 Selecting the source for control word 1 (bit 8-15) ................................................................ 4-15
4.3.1.1.5 Selecting the source for control word 2 (bit 16-23) .............................................................. 4-16
4.3.1.1.6 Selecting the source for control word 2 (bit 24-31) .............................................................. 4-17
4.3.1.1.7 Significance of control word- (1 and 2) commands .............................................................. 4-18
4.3.1.2 Status word (status word 1 and status word 2) .................................................................... 4-23
4.3.1.2.1 Introduction and application example .................................................................................. 4-23
4.3.1.2.2 Overview of the status word (status word 1 and status word 2) .......................................... 4-24
4.3.1.2.3 Selecting the destinations for the status word (bits 0 - 31) .................................................. 4-25
4.3.1.2.4 Significance of the status word messages ........................................................................... 4-26
4.3.1.3 Setpoints .............................................................................................................................. 4-28
4.3.1.4 Ac
tual values
........................................................................................................................ 4-29
4.3.2 Binary inputs ......................................................................................................................... 4-30
4.3.3 Binary outputs ...................................................................................................................... 4-30
4.3.5 Analog output ....................................................................................................................... 4-31
4.3.6 Serial interfaces .................................................................................................................... 4-34
4.3.6.1.1 Basic converter interface SST1 ............................................................................................ 4-34
4.3.6.1.2 Basic converter interface SST2 (A2-X117), see Section 9.6, Options ................................ 4-34
4.3.6.2 Dual-port RAM (DPR for SCB, CB, TB) ............................................................................... 4-34
4.3.9 Function selection (P052) ................................................................................................. 4-35
4.3.9.1 Generating the factory setting (P052 = 1 or P970 = 0) ..................................................... 4-35
4.3.9.2 Initialization (MLFB setting) (P052 = 2) .............................................................................. 4-37
4.3.9.3 Download or upread (P052 = 3) .......................................................................................... 4-39
4.3.9.4 Hardware configuration (P052 = 4) ................................................................................... 4-40
4.3.9.5 Drive setting (P052 = 5) .................................................................................................... 4-41
AoteWell Automation Sales Team
Buy Siemens PLC HMI Drives at AoteWell.com