5.8.3 Changing parameter values
Overview
You can modify the settings of the converter by changing the parameter values in the converter.
Precondition
The converter only permits changes to write parameters. Write parameters begin with a "P", e.g.
P45.
The value of a read-only parameter cannot be changed. Read-only parameters begin with an
"r", for example: r2.
Function description
Procedure
1. Select the menu to display and change parameter values.
2.
2. Select the parameter 󹪝lter.
2.
The converter only displays the most important parameters:
The converter displays all of the parameters to you:
3. When the parameter number 󹪞ashes, select the desired parameter number.
2.
4. When the parameter value 󹪞ashes, change the parameter value.
2.
You changed a parameter value.
Additional information
The converter immediately saves any changes so that they are protected against power failure.
Commissioning
5.8Handling the BOP 2 operator panel
SINAMICS G120C Converters
160 Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK

Table of Contents

Other manuals for Siemens SINAMICS G120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C and is the answer not in the manual?

Siemens SINAMICS G120C Specifications

General IconGeneral
Communication InterfacesPROFINET, PROFIBUS, USS, Modbus RTU
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Storage Temperature-40°C to +70°C
Power Range0.55 kW to 132 kW
Voltage Range380 V to 480 V
Output Voltage0 V to Supply Voltage
Frequency Range0 Hz to rated output frequency
Control ModesVector control with encoder
ProtectionOverload, overvoltage, undervoltage, short circuit, ground fault
Relative Humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating

Related product manuals