5.8.5 Entering the parameter number directly
Overview
The BOP‑2 o󹪜ers the possibility of setting the parameter number digit by digit.
Precondition
You are in the menu for displaying and changing parameter values.
The number of a given parameter 󹪞ashes in the BOP-2 display.
Function description
Procedure
1. Press the OK button until the 󹪝rst digit of the parameter number 󹪞ashes.
V
2.
2. Change the parameter number digit-by-digit.
If you press the OK button, the BOP‑2 jumps to the next digit.
2.2.
3. After you have entered all of the digits of the parameter number, press the OK button.
You set the parameter number directly.
Commissioning
5.8Handling the BOP 2 operator panel
SINAMICS G120C Converters
162 Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK

Table of Contents

Other manuals for Siemens SINAMICS G120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C and is the answer not in the manual?

Siemens SINAMICS G120C Specifications

General IconGeneral
Communication InterfacesPROFINET, PROFIBUS, USS, Modbus RTU
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Storage Temperature-40°C to +70°C
Power Range0.55 kW to 132 kW
Voltage Range380 V to 480 V
Output Voltage0 V to Supply Voltage
Frequency Range0 Hz to rated output frequency
Control ModesVector control with encoder
ProtectionOverload, overvoltage, undervoltage, short circuit, ground fault
Relative Humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating

Related product manuals