A.1.10 Firmware version 4.5
Table A-10 New functions and function changes in Firmware4.5
Function SINAMICS
G120 G120D
*&
&83
&8%
&8(
&8'
&8'
1 Support for the new Power Modules:
PM230 IP20 FSA … FSF
PM230 in a push-through FSA … FSC
- - -
2 Support for the new Power Modules:
PM240-2 IP20 FSA
PM240-2 in push-through FSA
- - -
3 New Control Units with PROFINET support -
4 Support of the PROFIenergy pro󹪝le -
5 Shared device support via PROFINET -
6 Write protection
7 Know-how protection
8 Adding a second command data set (CDS0 → CDS0 … CDS1)
(All other converters have four command data sets)
- - - - -
9 Position control and basic positioner - - - - -
10 Support of an HTL encoder - - - -
11 Support of an SSI encoder - - - - -
12 Failsafe digital output - - - -
A.2 Interconnecting signals in the converter
A.2.1 Fundamentals
The following functions are implemented in the converter:
Open-loop and closed-loop control functions
Communication functions
Diagnosis and operating functions
Every function comprises one or several blocks that are interconnected with one another.
Appendix
A.2Interconnecting signals in the converter
SINAMICS G120C Converters
Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK 461

Table of Contents

Other manuals for Siemens SINAMICS G120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C and is the answer not in the manual?

Siemens SINAMICS G120C Specifications

General IconGeneral
Communication InterfacesPROFINET, PROFIBUS, USS, Modbus RTU
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Storage Temperature-40°C to +70°C
Power Range0.55 kW to 132 kW
Voltage Range380 V to 480 V
Output Voltage0 V to Supply Voltage
Frequency Range0 Hz to rated output frequency
Control ModesVector control with encoder
ProtectionOverload, overvoltage, undervoltage, short circuit, ground fault
Relative Humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating