5. Wait until the converter has transferred the settings from the memory card.
2.
6. Back up the settings so that they are protected against power failure.
2.2.
2.
2.
7. Start to commission the safety functions.
2.2.2.
8. Enter the password for the safety functions.
2.2.
9. Con󹪝rm the setting of the safety functions.
2.2.
10.Exit commissioning of the safety functions.
2.2.
11.Back up the settings so that they are protected against power failure.
2.2.
2.
2.
12.Switch o󹪜 the converter power supply.
13.Wait until all LEDs on the converter are dark.
14.Switch on the converter power supply again.
15.Perform a reduced acceptance test.
Reduced acceptance after component replacement and 󹪝rmware change (Page417)
You have transferred the settings from the memory card to the converter.
Corrective maintenance
10.2Downloading the converter settings
SINAMICS G120C Converters
392 Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK

Table of Contents

Other manuals for Siemens SINAMICS G120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C and is the answer not in the manual?

Siemens SINAMICS G120C Specifications

General IconGeneral
Communication InterfacesPROFINET, PROFIBUS, USS, Modbus RTU
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Storage Temperature-40°C to +70°C
Power Range0.55 kW to 132 kW
Voltage Range380 V to 480 V
Output Voltage0 V to Supply Voltage
Frequency Range0 Hz to rated output frequency
Control ModesVector control with encoder
ProtectionOverload, overvoltage, undervoltage, short circuit, ground fault
Relative Humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating

Related product manuals