EasyManuals Logo

Siemens SINAMICS G120C User Manual

Siemens SINAMICS G120C
478 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #464 background imageLoading...
Page #464 background image
0RWRUL]HGSRWHQWLRPHWHUVHWSRLQW
DIWHUWKHUDPSIXQFWLRQJHQHUDWRU
0RWRUL]HGSRWHQWLRPHWHU
VHWSRLQWORZHU
0RWRUL]HGSRWHQWLRPHWHU
VHWSRLQWKLJKHU
,QSXWV2XWSXW3DUDPHWHU
S
U
S
023
FigureA-1 Example of a block: Motorized potentiometer (MOP)
Most of the blocks can be adapted to speci󹪝c applications using parameters.
You cannot change the signal interconnection within the block. However, the
interconnection between blocks can be changed by interconnecting the inputs of a block
with the appropriate outputs of another block.
The signal interconnection of the blocks is realized, contrary to electric circuitry, not using
cables, but in the software.
0DLQVHWSRLQW
0RWRUL]HGSRWHQWLRPHWHU
VHWSRLQWDIWHUWKH
UDPSIXQFWLRQJHQHUDWRU
0RWRUL]HG
SRWHQWLRPHWHU
VHWSRLQWORZHU
0RWRUL]HG
SRWHQWLRPHWHU
VHWSRLQWKLJKHU
352),GULYH
UHFHLYH3='
ELWE\ELW
S

U
U
S
U
S
023
FigureA-2 Example: Signal interconnection of two blocks for digital input 0
Binectors and connectors
Connectors and binectors are used to exchange signals between the individual blocks:
Connectors are used to interconnect "analog" signals (e.g. MOP output speed)
Binectors are used to interconnect digital signals (e.g. "Enable MOP up" command)
%,&2EORFN
%LQHFWRULQSXW
%LQHFWRURXWSXW
%LQHFWRUFRQQHFWRURXWSXW
&RQQHFWRURXWSXW
&RQQHFWRULQSXW
S[[[[
U[[[[
U[[[[
U[[[[
U[[[[
S[[[[
%,
&2
%2
&2%2
&,
FigureA-3 Symbols for binector and connector inputs and outputs
Binector/connector outputs (CO/BO) are parameters that combine more than one binector
output in a single word (e.g. r0052 CO/BO: status word 1). Each bit in the word represents
a digital (binary) signal. This summary reduces the number of parameters and simpli󹪝es
parameter assignment.
Binector or connector outputs (CO, BO or CO/BO) can be used more than once.
Appendix
A.2Interconnecting signals in the converter
SINAMICS G120C Converters
462 Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK

Table of Contents

Other manuals for Siemens SINAMICS G120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C and is the answer not in the manual?

Siemens SINAMICS G120C Specifications

General IconGeneral
Communication InterfacesPROFINET, PROFIBUS, USS, Modbus RTU
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Storage Temperature-40°C to +70°C
Power Range0.55 kW to 132 kW
Voltage Range380 V to 480 V
Output Voltage0 V to Supply Voltage
Frequency Range0 Hz to rated output frequency
Control ModesVector control with encoder
ProtectionOverload, overvoltage, undervoltage, short circuit, ground fault
Relative Humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating

Related product manuals