Gearbox
9.2 Motors with planetary gears
Synchronous Motors 1FK7
206 Configuration Manual, (PFK7S), Edition 12.2006, 6SN1197-0AD16-0BP1
Selection and ordering data
Weight Static
current
Maxi-
mum
current
SINAMICS Motor Module Power cable with complete shield
Motor terminal (and brake terminal) via
power connector
(without
brake)
(with
brake)
Rated
output
current
Motor type
(continued)
m m I
0
at M
0
T = 100 K
I
max
I
N
Order No.
For complete order no.,
see “SINAMICS S120”
Power
con-
nector
Motor
cable cross
section
2)
Order no.
Pre-assembled cable
kg/lb kg/lb A A A Size mm
2
1FK7032-5AK71-
11111
... 4.11/
9.06
4.47/
9.86
1.7 5 3 6SL312
7
-
7
TE13-0AA0 1 4 x 1.5 6FX
7
002-5
7
S01-....
1FK7034-5AK71-... 5.01/
11.05
5.37/
11.84
1.9 7.9 3 6SL312
7
-
7
TE13-0AA0 1 4 x 1.5 6FX
7
002-5
7
S01-....
1FK7040-5AK71-... 6.6/
14.55
7.61/
16.78
2.3 7.4 3 6SL312
7
-
7
TE13-0AA0 1 4 x 1.5 6FX
7
002-5
7
S01-....
1FK7042-5AK71-... 7.91/
17.44
8.62/
19.01
4.4 14.9 5 6SL312
7
-
7
TE15-0AA0 1 4 x 1.5 6FX
7
002-5
7
S01-....
1FK7060-5AH71-... 13.9/
30.65
15/
33.08
6.2 19 9 6SL312
7
-
7
TE21-0AA0 1 4 x 1.5 6FX
7
002-5
7
S01-....
1FK7063-5AH71-... 17.6/
38.81
19/
41.90
12 41 18 6SL312
7
-
7
TE21-8AA0 1 4 x 1.5 6FX
7
002-5
7
S01-....
1FK7080-5AH71-... 23.4/
51.60
24.6/
54.24
7.4 24 9 6SL312
7
-
7
TE21-0AA0 1 4 x 1.5 6FX
7
002-5
7
S01-....
1FK7083-5AH71-... 28.6/
63.06
31.2/
68.80
15 48 18 6SL312
7
-
7
TE21-8AA0 1 4 x 1.5 6FX
7
002-5
7
S01-....
Cooling:
Internal air cooling
External air cooling
0
1
Motor Module:
Single Motor Module
Double Motor Module
1
2
Power cable model:
MOTION-CONNECT 800
MOTION-CONNECT 500
8
5
Without brake cores
With brake cores
C
D
For length code as well as power and signal cables, see “MOTION-CONNECT cables and connections”. ....
1)
If the absolute encoder is used, M
rated
is reduces by 10%.
2)
The current carrying capacity of the Motor Module corresponds to
IEC 60204-1 for type of routing C under continuous operation condi-
tions with an ambient air temperature of +40 °C (104 °F), designed
for I
0
(100 K), PVC/PUR-insulated cable.

Table of Contents

Other manuals for Siemens SINAMICS S120

Related product manuals