EasyManua.ls Logo

Siemens SINAMICS S120 - Technical Data of the Holding Brake

Siemens SINAMICS S120
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motor components
6.3 Holding brake (option)
Synchronous Motors 1FK7
Configuration Manual, (PFK7S), Edition 12.2006, 6SN1197-0AD16-0BP1
83
6.3.6 Technical data of the holding brake
Table 6-14 Technical data of the holding brakes used for 1FK7 motors
Motor type Brake type Holding torque
at 120 °C
M
4
Direct current
at 20 °C
Opening time
with varistor
Closing time
with varistor
Highest
switched
energy
[Nm] [A] [ms] [ms] [J]
1FK7 CT permanent-magnet brakes
1FK701☐ HT03P 0,4 0,3 30 20 2
1FK7022 EBD 0.11 BN 1,0 0,3 30 20 8
1FK703☐ EBD 0.13 BN 1,3 0,4 50 30 17
1FK704 EBD 0.3 BV 3,2 0,6 70 30 74
1FK706 EBD 0.8 BK 13 0,8 100 50 400
1FK7080 EBD 1.5 BN 10 0,7 100 50 400
1FK7083
1FK7100
EBD 2 BY 22 0,9 200 60 1400
1FK7101
1FK7103
1FK7105
EBD 3.5 BV 41 1,0 300 70 3000
1FK7 HD spring-operated brakes
1FK7033 1EB 14–30 1,3 0,5 100 40 14
1FK704 1EB 20-40 4 0,6 150 50 96
1FK706 1EB 28-60 12 0,8 150 50 230
1FK708 1EB 35-80 22 1,2 200 60 700
Holding torque M4
The holding torque M
4
is the highest permissible torque with which the closed brake can be
loaded in steady-state operation without slip (holding function when motor is stationary).