Motor components
6.5 Drive coupling
Synchronous Motors 1FK7
90 Configuration Manual, (PFK7S), Edition 12.2006, 6SN1197-0AD16-0BP1
6.5.2 Technical data for the couplings
Table 6-18 Assignment of the drive couplings to the motors
Motor 1FK7
d
w
[mm]
1)
Rotex
GS
Type
Transferable torques with 80 or 92
Sh A
pinion
T
R
[Nm]
4)
T
KN
[Nm]
2)
T
Kmax
[Nm]
3)
1FK7022–... 9 9 1.8 3.6 2.6
1FK703–... 14 14 7.5 15 102
1FK704–... 19 19/24 10 20 -
1FK706–... 24 24/28 35 70 -
1FK708–... 32 28/38 95 190 -
1FK710–... 38 38/45 190 380 -
1) d
w
= diameter, motor shaft end
2) T
KN
= rated coupling torque
3) T
Kmax
= maximum coupling torque
4) T
R
= friction-locking torque (transferable torque with clamping hub for dw)
It may be necessary to use other gear rings (e.g. Shore hardness 80 Sh A). They must be