EasyManua.ls Logo

Siemens SINAMICS S120 - Page 23

Siemens SINAMICS S120
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motor Description
1.3 Selection and Ordering Data
Synchronous Motors 1FK7
Configuration Manual, (PFK7S), Edition 12.2006, 6SN1197-0AD16-0BP1
23
Motor type
(continued)
Static
current
Calculated
power
P
calc
= M
0
x
n
rated
/9550
SINAMICS Power Module Power cable with complete shield
Motor terminal (and brake terminal) via
power connector
Rated
output
current
I
0
at M
0
T=100 K
P
calc
for M
0
T=100 K
I
rated
at M
0
T=100 K
Order No.
For complete order no.,
see “SINAMICS S120”
Power
con-
nector
Motor
cable cross
section
3)
Order no.
Pre-assembled cable
A kW/HP A Size mm
2
1FK7032-5AF21... 1.7 0.36/0.5 2.3 6SL3210 - 1SB12-3UA0 1 4 x 1.5 6FX
7
002-5
7
A01-....
1FK7033-7AF21...
1FK7034-5AF21...
2.2
1.9
0.41/0.6
0.5/0.7
2.3
2.3
6SL3210 - 1SB12-3UA0
6SL3210 - 1SB12-3UA0
1
1
4 x 1.5
4 x 1.5
6FX
7
002-5
7
A01-....
6FX
7
002-5
7
A01-....
1FK7042-5AF21...
1FK7043-7AF21...
3.9
3.9
0.94/1.3
0.85/1.1
3.9
3.9
6SL3210 - 1SB14-0UA0
6SL3210 - 1SB14-0UA0
1
1
4 x 1.5
4 x 1.5
6FX
7
002-5
7
A01-....
6FX
7
002-5
7
A01-....
1FK7011-5AK21...
1FK7015-5AK21...
0.85
0.85
0.11/0.2
0.22/0.3
0.9
0.9
6SL3210 - 1SB11-0UA0
6SL3210 - 1SB11-0UA0
0.5
0.5
4 x 1.5
4 x 1.5
6FX5002-5ME00-....
2)
6FX5002-5ME00-....
2)
1FK7022-5AK21... 1.8 0.53/0.7 2.3 6SL3210 - 1SB12-3UA0 1 4 x 1.5 6FX
7
002-5
7
A01-....
Cooling:
Internal air cooling
0
Motor Module:
Single Motor Module
1
Power cable model:
MOTION-CONNECT 800
MOTION-CONNECT 500
8
5
Without brake cores
With brake cores
C
D
For length code as well as power and signal cables, see “MOTION-CONNECT cables and connections”. ....
1)
If the absolute encoder is used, M
rated
is reduced by 10%.
2)
This power cable is fitted with a connector with M17 thread at the
motor end and brake cores as standard (4 x 1.5 mm
2
+ 2 x 1.5 mm
2
).
3)
The current carrying capacity of the power cable corresponds to
IEC 60204-1 for type of routing C under continuous operating condi-
tions with an ambient air temperature of +40 °C (104 °F), designed
for I
0
(100 K), PVC/PUR-insulated cable.
4)
Motors in shaft height 20 are not available with a DRIVE-CLiQ inter-
face. The encoder systems are connected via the SMC (Sensor
Module Cabinet-Mounted).

Table of Contents

Other manuals for Siemens SINAMICS S120

Related product manuals