Application
2.2 Electrical connections
Synchronous Motors 1FK7
34 Configuration Manual, (PFK7S), Edition 12.2006, 6SN1197-0AD16-0BP1
Motors with DRIVE-CLiQ
Motors with DRIVE-CLiQ interfaces can be directly connected to the corresponding motor
module via the available MOTION-CONNECT DRIVE-CLiQ cables. This means that data
are transferred directly to the control unit.
(QFRGHULQWHUIDFHYLD'5,9(&/L4
3RZHUFDEOH
0RWRU
6,1$0,&66
'5,9(&/L4
˽
0RWRU
0RGXOHV
(
a
0
[9'&SRZHUVXSSO\
['5,9(&/L4VLJQDOFDEOH
Figure 2-6 Encoder interface with DRIVE-CLiQ
Motors without DRIVE-CLiQ
Motors without DRIVE-CLiQ require a cabinet-mounted sensor module for operation with
SINAMICS S120. The sensor modules evaluate the signals from the connected motor
encoders or external encoders and convert them to DRIVE-CLiQ. In conjunction with
motor encoders, the motor temperature can also be evaluated using sensor modules.
For additional information, refer to the SINAMICS Manual.
6LJQDOFDEOH
3RZHUFDEOH
6,1$0,&66
0
'5,9(
&/L4
6HQVRU0RGXOH&DELQHW
&RQQHFWLQJWKHHQFRGHUWKURXJKWKH6HQVRU0RGXOH&DELQHW
˽
0RWRU
(
a
0RWRU
0RGXOHV
Figure 2-7 Encoder interface without DRIVE-CLiQ