8. The "I/O address" column displays the start address for every drive object.
Select the start address of the data of the drive object to be read. In the example, "268" is
proposed.
If the complete data of the publisher is not to be read, set this using the "Length" column.
Alternatively, you can shift the start address of the access, so that the required data can
be read out from the center section of the telegram component of the drive object.
Figure A-15 Configuring the slave-to-slave communication nodes
Communication
A.1 Communication
Industrial Security
132 Configuration Manual, 08/2017, A5E36912609A