Exceptions to write protection
Some functions are free from write protection, such as:
Deactivating/activating the write protection
Changing the access level (p0003)
Saving parameters (p0971)
Safe removal of the memory card (p9400)
Restoring the factory setting
Transfering the settings from an external data backup, e.g. upload into the drive unit from
a memory card.
The parameters that are not write protected are in the converter List Manual in chapters
"Parameters for write protection and know-how protection" and "Parameters with
WRITE_NO_LOCK".
Overview of important parameters
Note
For a description of the parameters, see the converter List Manual.
Parameter Function
r7760 Write protection / know-how protection status
p7761 Write protection
p7762 Write protection multi-master fieldbus system access behavior
5.2.2 Know-how protection
5.2.2.1 Overview
The "know-how protection" (KHP) function prevents, for example, strictly confidential company
knowledge for configuration and parameter assignment from being read by unauthorized
persons.
The know-how protection requires a password. The password must comprise at least 1 and a
maximum of 30 characters.
The know-how protection is a pure online function. Therefore, establish a direct connection to
the Control Unit before setting the password.
Security measures for SINAMICS
5.2 Write protection and know-how protection
Industrial Security
34 Configuration Manual, 08/2017, A5E36912609A