Parameter Description
p2051[0...24] CI: IF1 PROFIdrive PZD send word
r2053[0...24] IF1 PROFIdrive diagnostics PZD send word
r2054 PROFIBUS status
p8835 CBE20 firmware selection
p8839[0...1] PZD interface hardware assignment
p8840 COMM BOARD monitoring time
r8850[0...19] CO: IF2 PZD receive word
p8851[0...24] CI: IF2 PZD send word
r8853[0...24] IF2 diagnostics PZD send
r8854 COMM BOARD state
p8920[0...239] PN Name of Station
p8921[0...3] PN IP address
p8922[0...3] PN default gateway
p8923[0...3] PN Subnet Mask
p8924 PN DHCP mode
p8925 PN interfaces configuration
p8940[0...239] CBE2x Name of Station
p8941[0...3] CBE2x IP address
p8942[0...3] CBE2x Default Gateway
p8943[0...3] CBE2x Subnet Mask
p8944 CBE2x DHCP mode
p8945 CBE2x interfaces configuration
A.1.5 Communication via EtherNet/IP
A.1.5.1 Overview
EtherNet/IP is real-time Ethernet, and is mainly used in automation technology.
Communication via EtherNet/IP is possible via the following connections:
Via the onboard interface X150
Via the Option Board Ethernet CBE20
Possible drive units:
CU320-2 PN
CU320-2 DP
A.1.5.2 Connect drive device to Ethernet/IP
In order that your drive can be connected to a control system via Ethernet, your control system
requires a generic I/O module for cyclic communication via EtherNet/IP. You manually create
this generic I/O module in the control system.
Communication
A.1 Communication
Industrial Security
Configuration Manual, 08/2017, A5E36912609A 189