Detailed description
2.12 Block descriptions
Power Line Basic PLC Program (P3)
2-134 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Parameter:
WVar1=FunctionNumber
This function number represents a PI service:
1: TMCRTO (create tool)
2: TMFDPL (search for empty location for loading):
3: TMMVTL (prepare magazine location for loading, unload tool)
4: TMFPBP (search for location)
5: TMGETT (search for tool number)
6: TSEARC (search for tool)
7 ...
10:
Reserved
WVar2=SemaphorValue
0: Reset semaphore
1: Test and set semaphore
Parameterization:
Parameterization
Signal Type Value range Meaning
PIService ANY PI.MMCSEM Create new cutting
edge
Unit INT 1, 2 to 10 Channel
WVar1 INT 1 to 10 FunctionNumber
WVar2 Word 0, 1 SemaphoreValue