EasyManuals Logo

Siemens SINUMERIK 804D sl Function Manual

Siemens SINUMERIK 804D sl
2050 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1375 background imageLoading...
Page #1375 background image
Detailed Description
2.12 Block descriptions
PLC Basic Program Solution Line (P3 sl)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-181
Fig. 2-31 Star/delta switchover
More information about motor speed adjustment can be found in:
References:
/FB/ Description of Functions, Basic Machine; Spindles (S1);
Section: Configurable Gear Adjustments
/FB/ Description of Functions, Basic Machine; Velocities, Setpoint/Actual Value Systems,
Closed-Loop Control (G2)
Error message
If the parameter "SpindleIFNo" is not in the permissible range, the PLC is stopped with
output of interrupt message number 401702.
Special features
When parameterizing "TimeVal" with the value 0, a default value of 100 ms is used. With a
value of less than 50 ms, the minimum setting of 50 ms is applied.
The block must be called unconditionally.
Note
Switchover does not take place if the spindle is in an axis mode such as M70, SPOS.

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals